Specification |
Ports & interfaces |
---|
Supported storage drive interfaces | SAS, Serial ATA | Internal SAS ports | 2 | Host interface | PCI Express x16 | PCI Express slots version | 4.0 | Performance |
---|
RAID levels | 0, 1, 5, 6, 10, 50, 60 | SSD support | Yes | S.M.A.R.T. support | Yes | Number of devices supported | 240 | Mean time between failures (MTBF) | 3000000 h | Form factor | MD2 | Data transfer rate | 6 Gbit/s | Channels quantity | 16 channels | Certification | Australia/New Zealand RCM (AS/NZS CISPR 32; CISPR 32:2015, Class A; AS/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN/CSA C22.2 No. 62368-1-14), USA/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3/2015.04, Class A; V-4/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020) | Data transmission |
---|
Data transfer rate | 6 Gbit/s | Technical details |
---|
RAID levels | 0, 1, 5, 6, 10, 50, 60 | SSD support | Yes | S.M.A.R.T. support | Yes | Number of devices supported | 240 | Form factor | MD2 | Channels quantity | 16 channels | Compliance certificates | RoHS, WEEE | Design |
---|
Form factor | MD2 | Endurance |
---|
Mean time between failures (MTBF) | 3000000 h | Power |
---|
Power consumption (typical) | 25 W | Certificates |
---|
Certification | Australia/New Zealand RCM (AS/NZS CISPR 32; CISPR 32:2015, Class A; AS/NZS CISPR 32:2015, Class A), Canada EMC (ICES-003:2016 Issue 6: 2016, Class A; CAN/CSA CISPR 22-10; CISPR 22:2008), Europe (CE) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020), Korea (KN32/KN35), Taiwan BSMI (CNS 13438; CNS15663), USA/Canada Safety (UL Listed) (UL 62368-1, Second Edition; CAN/CSA C22.2 No. 62368-1-14), USA/Canada (FCC) (47 CFR FCC Part 15, Subpart B, Class A; ANSI C63.4:2014; CISPR 32:2008) CB (IEC 62368-1:2014 (Second edition); EN 62368-1:2014+A11: 2017), Japan (V-3/2015.04, Class A; V-4/2012.04; VCCI-CISPR 32:2016; CISPR 32:2015), Morocco (CMIM) (EN 55024, EN 55032, EN 55035; EN 55032:2015 +AC:2016, Class A; EN 55024:2010 +A1:2015; EN 55035:2017 +A11:2020) | System requirements |
---|
Server operating systems supported | SUSE Linux Enterprise Server | Windows operating systems supported | Yes | Linux operating systems supported | Yes | Other operating systems supported | VMware vSphere ESXi | Operational conditions |
---|
Operating temperature (T-T) | 0 - 55 °C | Operating relative humidity (H-H) | 5 - 90% | Weight & dimensions |
---|
Width | 155.6 mm | Depth | 111.1 mm | Other features |
---|
Other operating systems supported | VMware vSphere ESXi |
|