- Ideal for providing uninterrupted power in critical marine applications
- DNV type approved
- Hot-swappable, front-accessible, user replaceable batteries
- Manual bypass switch
- Operating temperature up to 55°C
Provides early-warning fault analysis ensuring proactive component replacement.
Designed for harsh electrical environments to save battery life.
Allows for reduced battery recharge time, prevents disturbances on the distribution system by correcting the power factor, protects the battery against damage caused by deep discharge and provides backfeed protection.
Allows for reduced battery recharge time, prevents disturbances on the distribution system by correcting the power factor, protects the battery against damage caused by deep discharge and provides backfeed protection.
Provide easy-to-read status of the unit and utility power conditions.
Provide easy-to-read status of the unit and utility power conditions.
Provide easy-to-read status of the unit and utility power conditions.
User assignable inputs allow other equipment alarms to be monitored through the power system controller
If you are like most businesses, you want your systems up and running during your busiest hours. In order to accommodate your busy schedule, APC offers an option to schedule services off hours. We will work with you to find a time when servicing your system is least likely to impact your productivity, saving your business time and money.
Small UPS footprint provides maximum usage of valuable electrical room floorspace
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency
Step by step navigation and menu screens for critical system information and data. Information is easy to access and presented in a very intuitive way.
Horizontal console port servers can be cascaded to manage up to 1,024 devices.
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Warns when a battery is not available to provide backup power.
Warns when a battery is not available to provide backup power.
Registering license keys unlocks the features of the data center management software.
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Delivers higher availability through redundant batteries.
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Simplifies installation and UPS maintenance while minimizing space requirements.
Simplifies installation and UPS maintenance while minimizing space requirements.
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Prevents unauthorized access to the UPS.
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Provides management of the UPS via a serial port.
Provides management of the UPS via a serial port.
Prolongs battery life by regulating the charge voltage according to battery temperature.
Fast, easy installation takes the guesswork out of configuration for first-time users
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Baseline data enables you to better understand your current situation and to measure improvements gained by infrastructure utilization and energy efficiency changes.
| Power | |
|---|---|
| Output power | 1540 W |
| Input operation voltage (min) | 100 V |
| Input operation voltage (max) | 280 V |
| Output operation voltage (min) | 220 V |
| Output operation voltage (max) | 240 V |
| Surge energy rating | 480 J |
| Efficiency | 92% |
| Emergency Power Off (EPO) | Yes |
| Output voltage Total Harmonic Distortion (THD) | 3% |
| Crest factor | 3:1 |
| Output power capacity | 2.2 kVA |
| Ports & interfaces | |
| Cable length | 2.5 m |
| AC outlets quantity | 10 AC outlet(s) |
| AC outlet types | C13 coupler, C19 coupler |
| Number of output IEC jumpers | 2 |
| Ethernet LAN (RJ-45) ports | 1 |
| Performance | |
| Noise level | 55 dB |
| Audible alarm(s) | Yes |
| Features | |
| Output power | 1540 W |
| Input operation voltage (min) | 100 V |
| Input operation voltage (max) | 280 V |
| Output operation voltage (min) | 220 V |
| Output operation voltage (max) | 240 V |
| Surge energy rating | 480 J |
| Efficiency | 92% |
| Emergency Power Off (EPO) | Yes |
| Output voltage Total Harmonic Distortion (THD) | 3% |
| Noise level | 55 dB |
| Crest factor | 3:1 |
| Audible alarm(s) | Yes |
| Output power capacity | 2.2 kVA |
| Input frequency | 50/60 Hz |
| Battery | |
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery recharge time | 2.5 h |
| Design | |
| Rack capacity | 3U |
| Form factor | Rackmount |
| Product colour | Black |
| Certification | CE, DNV, EN 50091-1, EN 50091-2, EN 55022 Cl. A, EN 60950, EN 61000-3-2. |
| Cable length | 2.5 m |
| Operational conditions | |
|---|---|
| Operating temperature (T-T) | 0 - 55 °C |
| Storage temperature (T-T) | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Technical details | |
| Harmonized System (HS) code | 85078000 |
| Compliance certificates | RoHS |
| Packaging data | |
| Package dimensions (WxDxH) | 603 x 980 x 347 mm |
| Package weight | 63.6 kg |
| Weight & dimensions | |
| Weight | 54.5 kg |
| Width | 130 mm |
| Package weight | 63.6 kg |
| Height | 432 mm |
| Depth | 660 mm |
| Logistics data | |
| Harmonized System (HS) code | 85078000 |
| Certificates | |
| Certification | CE, DNV, EN 50091-1, EN 50091-2, EN 55022 Cl. A, EN 60950, EN 61000-3-2. |
| Other features | |
| Dimensions (WxDxH) | 130 x 660 x 432 mm |
| Package dimensions (WxDxH) | 603 x 980 x 347 mm |
| Nominal output voltage | 230 V |
| Nominal input voltage | 230 V |
| Product |
APC Smart-UPS RT 2200VA 230V - Marine
Login for pricing
|
APC Smart-UPS X SMX2200RMHV2U - 2200VA...
Login for pricing
|
Recommended
APC Smart-UPS X SMX3000RMHV2U - 3000VA...
Login for pricing
|
Bestseller
APC Smart-UPS X SMX3000RMHV2UNC - 3000...
Login for pricing
|
Popular
APC Smart-UPS X SMX3000HV - 3000VA, 8x...
Login for pricing
|
Hot Product
APC Smart-UPS On-Line SRT3000XLI - 300...
Login for pricing
|
|---|---|---|---|---|---|---|
| SKU |
SURTD2200XLIM
|
SMX2200RMHV2U
|
SMX3000RMHV2U
|
SMX3000RMHV2UNC
|
SMX3000HV
|
SRT3000XLI
|
| Manufacturer |
APC
|
APC
|
APC
|
APC
|
APC
|
APC
|
| Form factor |
Rackmount
|
Rackmount/Tower
|
Rackmount/Tower
|
Rackmount/Tower
|
Rackmount/Tower
|
Tower
|
| Output power capacity |
1200VA to 4000VA
|
1200VA to 4000VA
|
1200VA to 4000VA
|
1200VA to 4000VA
|
1200VA to 4000VA
|
1200VA to 4000VA
|
| Product colour |
Black
|
Black
|
Black
|
Black
|
N/A
|
Black
|
| Output power |
1500W to 2000W
|
1500W to 2000W
|
2000W to 3000W
|
2000W to 3000W
|
2000W to 3000W
|
2000W to 3000W
|
| UPS topology |
N/A
|
Line-interactive
|
Line-interactive
|
Line-interactive
|
Line-interactive
|
Double-conversion (Online)
|